|
|
|
|
The Red Lion PM-50 series PM500D0400800F00 is a digital input graphical panel meter. It features a 4.3" touchscreen color display with 1/8 DIN housing. Features Modbus communications, WiFi, and Ethernet. It's ideal for increasing productivity, showing plant floor data, project scheduling, and process improvements. It is able to accommodate count and rate inputs.
Features
- Universal Digital Input - count and rate
- Dual Solid State Outputs - adjustable for sinking or sourcing applications
- DC powered (AC powered with optional module)
- 4.3" (1/8 DIN) 18 bit color display with touchscreen
- Multiple displays
- Two programmable user inputs
- Alarm notification - Display color change, push messaging
- Nonvolatile memory retains all programmable parameters and display values
- Data access point: WiFi, RS-485/Modbus, and optional Ethernet or RS-232
- Uses Modbus protocol (RTU and ASCII)
- High compression spring-clamp terminal block connection
- NEMA 4X / IP 65 sealed front panel
- 2 Year manufacturer's warranty on design & manufacturing defects
Red Lion PM-50 Panel Meter Downloads
Specifications
Display Type: Color TFT w/ resistive analog touch screen Pixels: 480 x 272 Brightness: 420 cd/m2 LED Backlight Life (at room temperature): 30,000 Hrs Power Requirements Input Voltage: 10-30V DC Max Power: 4.6 Watts Max Power w/ Modules: 12 Watts Host Isolation: 500 Vrms for 1 min to all inputs and outputs Sensor Power +24 VDC, ±5% @ 50 mA max. Signal Inputs
Software configurable input types including switch contacts, TTL outputs, magnetic pickups and all standard RLC sensors. Inputs are configurable for current sinking or current sourcing outputs with input filtering for low frequency signals or switch contact debounce. Not isolated from the sensor input common.
Logic: Input trigger levels VIL = 1.2 V max.; VIH = 3.75 V min. Sink: Adds internal 7.8 KΩ pull-up resistor to +5 VDC, 0.7 mA max Source: Adds internal 3.9 KΩ pull-down resistor, 7.3 mA max. at 28 VDC, VMAX = 30 VDC Magnetic Pickup: VIN_PK = 200 mV; VIN_HSYS = 100 mV; Must also have SRC selection turned on through software VMAX = ± 40 VPEAK or 28 Vrm Dual Count Modes: When any dual count mode is used, then User Inputs 1 and/ or 2 will accept the second signal of each signal pair. The user inputs do not have the Logic/Mag, HI/LO Freq, and Sink/ Source software selections. The user inputs are inherently alogic input with no low frequency filtering implemented in software. The user input may only be selected for sink/source by the User Input Active parameter. Counter Displays Display Range: -99,999,999 to 999,999,999 Over Range Display: Overrange Under Range Display: Underrange Display Designators: Cnt-A, Cnt-B, Cnt-C Maximum Count Rates: 50% duty cycle If Setpoints Disabled: 35 KHz for all modes except Quadrature x4 (32 KHz)If Setpoint(s) Enabled: 20 KHz for any mode except Quadrature x1 (19 KHz), Quadrature x2 (17 KHz) and Quadrature x4 (10 KHz)Total: Up to 9 Digits Rate Displays Maximum Frequency: 50 KHz Minimum Frequency: 0.001 Hz Display Update Time: 0.1 to 999.9 seconds Accuracy: +/-0.01% Total: Up to 6 Digits Memory Memory Card: microSD slot accepts up to 32 GB capacity cards in FAT16 / FAT32 format RS485 Serial Port Baud Rate: Up to 115,200 Data Format: 7/8 bit; odd, even, or no parity; 1 or 2 stop bits Isolation: 500 Vrms to sensor, user power and digital inputs. Not isolated to solid state outputs WiFi Capabilities WiFi: Power output up to 20.5 dBm Frequency: 2412-2484 MHz WiFi Compliance: TCP/IP; 802.11 b/g/n On Board Dual SSR Outputs Sinking Mode: Type: Switched DC, N-channel open drain MOSFET
Max Sink Current: 100 mA
VDS ON: 0.3 V @ 100 mA VDS MAX: 30 VDC Offstate Leakage Current: 0.5 mA max. Sourcing Mode: Type: Switched DC, P-channel open source MOSFET Max Source Current: 100 mA VDS ON: 0.3 V @ 100 mA VDS MAX: 30 VDC Offstate Leakage Current: 0.5 mA max
Standards Compliance CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC/EN 61010-1 RoHS Compliant FCC ID #: 2AC7Z-ESP32WROOM32U UL Listed: File #E317425 Type 4X Indoor rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Physical Operating Temperature: -10 C to 55 C (14 F to 131 F) Storage Temperature: -20 C to 60 C (-4 F to 140 F) Humidity: 85% max. relative humidity (non-condensing) Altitude: Up to 2000 meters Vibration to IEC 68-2-6: Operational 5-500 Hz, 2 g Shock to IEC 68-2-27: Operational 20 g (10 g relay) Installation Category II, Pollution Degree 2 as defined in IEC/EN 60664-1Dimensions (without modules): 3.74" Width x 3.23" Height x 4.08"
The touchscreen display features a status bar and menu selections. Different displays can be accessed by swiping across the screen like a smart device. Touchscreen buttons may be hidden during operation to avoid them accidentally being touched. A programming wizard assists the set-up process. External modules can be installed in the field to provide power or communication options.
|
|
|
|
|
|
|