The Red Lion PAXTM110 PAX series panel meter can be used as an elapsed or preset timer. It has a 6 digit, green LED display in a 1/8 DIN housing. There are two inputs with 23 timing ranges, with the ability to be a dual or quad output timer with an option card. Communication and bus capabilities are available through option cards, including RS232, RS485, Modbus, DeviceNet, and Profibus-DP. There are 5 function keys on the front, with 3 being programmable to meet the needs of the application. Four setpoint outputs are possible with an optional digital output card. DC powered
Features
- 1/8 DIN Housing
- 6 Digit, Green LED Display
- Elapsed Timer w/Preset Capability
- Counter w/Preset Capability
- Cycle Counting Capability
- Programmable Function Keys/User Inputs
- 4 Setpoint Alarm Outputs (w/Option card)
- Communication & Bus Capability (w/Option card)
- Crimson Programming Software
- 11 to 36 VDC (24 VDC nominal) Input Power
- NEMA 4X/IP65 - Front Panel
- Can Switch Between Parameter Lists
- Inputs Can be Switch Contacts, CMOS & TTL Circuit Outputs
- Parameters Can be Completely or Partially Locked After Setup
- Not made to directly command motors, valves or actuators without safeguards
Red Lion PAX Series Timer User Manual
Specifications
Display 6 digit, 0.56" (14.2 mm) standard green LED Annunciators: TMR- Timer, CNT- Cycle Counter SP1 - setpoint 1 output state, SP2 - setpoint 2 output state, SP3 - setpoint 3 output state, SP4 - setpoint 4 output state Power Requirements DC Power: 11 to 36 VDC, 14 W AC Power: 24 VAC, +/- 10%, 50/60 Hz, 15 VA Isolation: 500 Vrms for 1 min. to all inputs and outputs Sensor Power 12 VDC, +/-10%, 100 mA max. Short circuit protected Memory Nonvolatile E2PROM retains programmable parameters & display values User Inputs Three programmable user inputs Logic inputs configurable as Current Sinking (active low) or Current Sourcing (active high) through a single plug jumper. Current Sinking (active low): VIL = 0.9 V max., 22 KOhm pull-up to +12 VDC. Current Sourcing (active high): VIH = 3.6 V min., 22 KOhm pull-down, Max. Continuous Input: 30 VDC. Isolation To Timer Input Common: Not isolated Response Time: 10 msec Timer Display Timer Range: 23 Selectable Ranges Timing Accuracy: +/- 0.01% Minimum Digit Resolution: 0.001 Sec. Maximum Least Significant Digit Resolution: 1 Hr. Maximum Display: 999999 Cycle Counter Display Counter Range: 0 to 999999 Digit Resolution: 1 cycle Maximum Count Rate: 50 Hz Timer Inputs A & B Logic inputs configurable as Current Sinking (active low) or Current Sourcing (active high) via a single plug jumper. Current Sinking (active low): VIL = 0.9 V max., 22 KOhm pull-up to +12 VDC. Current Sourcing (active high): VIH = 3.6 V min., 22 KOhm pull-down, Max. Continuous Input: 30 VDC. Timer Input Pulse Width: 1 msec min. Timer Start/Stop Response Time: 1 msec max. Filter: Software filtering provided for switch contact debounce. Filter enabled or disabled through programming. If enabled, filter results in 50 msec start/stop response time for successive pulses on the same input terminal Standards Compliance CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A EN 61010-1: General Requirements
EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component: File #E179259 UL Listed: File #E137808 Type 4X Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 60 C (-40 F to 140 F) Humidity: 85% max. relative humidity (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g.
Shock to IEC 68-2-27: Operational 25 g (10 g relay). Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, IP20 Touch Safe, Installation Category II, Pollution Degree 2, One piece bezel/case; flame resistant; Synthetic rubber keypad; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. Dimensions: 1.95" x 3.8" x 4.2"
|
|
|
|
|
|
|