The Red Lion PAXLSG00 PAX LSG Lite series strain gage/millivolt panel meter has a 3 1/2 digit, red LED display in a 1/8 DIN housing. This panel meter can display variables measured with strain gages, such as pressure, load, and force. It has broad range scaling and is ideal for a number of strain gage resistances and bridge configurations. The built in excitation is jumper selectable at 5 or 10 VDC and powers up to four full 350 Ohm bridges. This device can also be used for single ended or differential millivolt input applications. AC powered.
Features
- 1/8 DIN Housing
- 3 1/2 Digit, Red LED Display
- High Sensitivity, 10 mV Full Scale
- Built in Excitation 5 or 10 VDC
- Selectable Decimal Points
- Over Range Indication
- NEMA 4X/IP65 - Front Panel
Red Lion PAX LSG Lite Series User Manual
Specifications
Display 3-1/2 digit, 0.56" (14.2 mm) red LEDs Power Requirements AC Power: 85 to 250 VAC, 50/60 HZ, 6 VA Isolation: 2300 Vrms for 1 min. to all inputs. Input Signal Single-ended or differential input, +/-2.0 V max. Gain (Sensitivity) is adjustable from 200 Units of Numerical Readout/millivolt input (gives full scale readout of 1999 at 10 mV input), to less than 1 Unit of Numerical Readout/mV (gives full scale readout of 1999 at 2.0 V input). Maximum common mode voltage swing with respect to signal ground, 0 to 7 V Input Impedance: 100 MOhm Linearity: +/-(0.05% +/-1 digit) Reading Rate: 2.5 updated readings / second, nominal. Response Time: 2 seconds to settle from step input. Low Frequency Noise Rejection Normal Mode Rejection: 84 dB @ 50/60 Hz Common Mode Rejection: 50 dB with respect to excitation common; 110 dB with respect to earth ground Excitation Supply Jumper Selectable: 5 VDC @ 60 mA max., +/-2% 10 VDC @ 120 mA max., +/-2% Temperature coefficient (ratio metric): 20 ppm/°C max Standards Compliance UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1 UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95 Type 4X Enclosure rating (Face only), UL50 IECEE CB Scheme Test Certificate # US/8843A/UL IECEE CB Scheme Test Report # 04ME11209-20041018 IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1. IP65 Enclosure rating (Face only), IEC 529 IP20 Enclosure rating (Rear of unit), IEC 529 Electromagnetic Compatibility: See user manual Physical Operating Temperature: 0 C to 60 C (32 F to 140 F) Storage Temperature: -40 C to 80 C (-40 F to 176 F) Humidity: 85% max. relative humidity (non-condensing) Span Temperature Coeff.: 100 PPM/°C Offset Temperature Coeff.: 100 PPM/°C Vibration to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2 g's. Shock to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, IP20 Touch safe, Installation Category II, Pollution Degree 2, One piece bezel/case; flame resistant; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. Dimensions: 1.95" x 3.8" x 4.2"
|
|
|
|
|
|
|