Home > Panel Meters > PAX Lite 1/8 DIN Panel Meters >

Red Lion Strain Gage Panel Meter


Red Lion Strain Gage Panel Meter
Red Lion PAXLSG00 Strain Gage Panel Meter
 
Alternative Views:


Price: $337.00
Note: Call 800-966-2345 for Lead Time
MFG P/N: PAXLSG00
MFG: Red Lion
Weight (lbs): 0.65



Availability:
In Stock
Product Code: PAXLSG00
Qty:

Description
 

The Red Lion PAXLSG00 PAX LSG Lite series strain gage/millivolt panel meter has a 3 1/2 digit, red LED display in a 1/8 DIN housing. This panel meter can display variables measured with strain gages, such as pressure, load, and force. It has broad range scaling and is ideal for a number of strain gage resistances and bridge configurations. The built in excitation is jumper selectable at 5 or 10 VDC and powers up to four full 350 Ohm bridges. This device can also be used for single ended or differential millivolt input applications. AC powered.

Features

  • 1/8 DIN Housing
  • 3 1/2 Digit, Red LED Display
  • High Sensitivity, 10 mV Full Scale
  • Built in Excitation 5 or 10 VDC
  • Selectable Decimal Points
  • Over Range Indication
  • NEMA 4X/IP65 - Front Panel

Red Lion PAX LSG Lite Series User Manual

Specifications

Display
3-1/2 digit, 0.56" (14.2 mm) red LEDs
Power Requirements
AC Power: 85 to 250 VAC, 50/60 HZ, 6 VA
Isolation: 2300 Vrms for 1 min. to all inputs.
Input Signal
Single-ended or differential input, +/-2.0 V max. Gain
(Sensitivity) is adjustable from 200 Units of Numerical Readout/millivolt input
(gives full scale readout of 1999 at 10 mV input), to less than 1 Unit of
Numerical Readout/mV (gives full scale readout of 1999 at 2.0 V input).
Maximum common mode voltage swing with respect to signal ground, 0 to 7 V
Input Impedance: 100 MOhm
Linearity: +/-(0.05% +/-1 digit)
Reading Rate: 2.5 updated readings / second, nominal.
Response Time: 2 seconds to settle from step input.
Low Frequency Noise Rejection
Normal Mode Rejection: 84 dB @ 50/60 Hz
Common Mode Rejection: 50 dB with respect to excitation common;
110 dB with respect to earth ground
Excitation Supply
Jumper Selectable: 5 VDC @ 60 mA max., +/-2%
10 VDC @ 120 mA max., +/-2%
Temperature coefficient (ratio metric): 20 ppm/°C max
Standards Compliance
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Certificate # US/8843A/UL
IECEE CB Scheme Test Report # 04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
IP20 Enclosure rating (Rear of unit), IEC 529
Electromagnetic Compatibility: See user manual
Physical
Operating Temperature: 0 C to 60 C (32 F to 140 F)
Storage Temperature: -40 C to 80 C (-40 F to 176 F)
Humidity: 85% max. relative humidity (non-condensing)
Span Temperature Coeff.: 100 PPM/°C
Offset Temperature Coeff.: 100 PPM/°C
Vibration to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2 g's.
Shock to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions
Altitude: Up to 2000 meters
Construction: NEMA 4X/IP65 outdoor use, IP20 Touch safe, Installation Category II,
Pollution Degree 2, One piece bezel/case; flame resistant;
panel gasket & mounting clip
Connection: High Compression Cage-Clamp Terminal Block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
Dimensions: 1.95" x 3.8" x 4.2"

Panel Meter Comparison Chart