Description
 

The Red Lion PAXLIT00 PAX LIT Lite series 5 Amp current panel meter has a 3 1/2 digit, red LED display in a 1/8 DIN housing . This panel meter is designed to measure large AC currents. It measures up to 5 Amps on its own, or up to 1999 Amps with an external current transformer. Scaling is possible, and the decimal point location can be selected via DIP switch. The display can show a minus sign if the current is in the negative. AC powered. Accessory shunts are available for higher current ranges.

Features

  • 1/8 DIN Housing
  • 3 1/2 Digit, Red LED Display
  • Built In Scaling Provisions
  • Selectable Decimal Point Location
  • Auto Zeroing Circuits
  • Over-Range Indication
  • NEMA 4X/IP65 - Front Panel

Red Lion PAX LIT Lite Series User Manual

Specifications

Display
3 1/2 digit, 0.56" (14.2 mm) red LEDs
Power Requirements
115 or 230 VAC, switch selectable. Allowable power line variation
+/-10%, 50/60 Hz, 6 VA.
Isolation: 2300 Vrms for 1 min. between input and supply
Working Voltage: 300 V max., CAT II
Signal Input
Range: 0 to 5 Amps AC @ 45 to 400 Hz
Resolution: 2.5 mA
Working Voltage: 300 V max., CAT II
Accuracy: +/-(0.5% of reading + 5 digits)
Max Shunt Current: 50 Amps for 1 sec.; 8 Amps continuous
Response Time to Step Change Input: 1 sec. nominal
Reading Rate: 2.5 readings/sec., nominal
Standards Compliance
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report # 04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Electromagnetic Compatibility: See user manual
Physical
Operating Temperature: 0 C to 60 C (32 F to 140 F)
Storage Temperature: -40 C to 80 C (-40 F to 176 F)
Humidity: 85% max. relative humidity (non-condensing)
Vibration to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2 g's.
Shock to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions
Altitude: Up to 2000 meters
Construction: NEMA 4X/IP65 outdoor use, Installation Category II, Pollution Degree 2,
One piece bezel/case; flame resistant; panel gasket & mounting clip
Connection: High Compression Cage-Clamp Terminal Block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
Dimensions: 1.95" x 3.8" x 4.2"