|
|
|
|
The Red Lion PAXH0100 PAX series AC voltage and current panel meter has a 5 digit, green LED display in a 1/8 DIN housing. The brightness of the display is adjustable to fit the surrounding conditions. The signal totalizer(integrator) is used for calculating a time-input product or the accumulation of batch weighing operations. Separate option cards create the possibility of four setpoint outputs and communications capabilities. The front panel has 5 function keys, with 3 of them being programmable. This unit is not designed to directly command motors, valves or actuators without safeguards. AC powered
Features
- AC True RMS Voltage & Current Meter
- 4 Voltage Ranges (300 VAC max)
- 5 Current Ranges (5A max)
- 1/8 DIN Housing
- 5 Digit, Green LED Display
- 16 Point Scaling for Non-Linear Processes
- Programmable Function Keys/User Inputs
- 4 Setpoint Alarm Outputs (w/Option card)
- Communication & Bus Capabilities (w/Option card)
- Retransmitted Analog Output (w/Option card)
- Crimson Programming Software
- Accepts AC or DC Coupled Inputs
- 3 Way Isolation- Power, Input, & Outputs
- 16 Bit Resolution A/D Converter
- 85 to 250 VAC Input
- NEMA 4X/IP65 - Front Panel
- MAX & MIN Reading Memory w/Programmable Capture Time
- Option Cards Field Upgradeable
Red Lion PAX Series Analog Meter User Manual
Specifications
Display 5 digit, 0.56" (14.2 mm) standard green LEDs, (-19999 to 99999) Annunciators: MAX, MIN, TOT, SP1 - setpoint alarm 1 active, SP2 - setpoint alarm 2 active, SP3 - setpoint alarm 3 active state, SP4 - setpoint alarm 4 active Power Requirements AC Power: 85 to 250 VAC, 50/60 Hz, 15 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. Memory Nonvolatile E2PROM retains programmable parameters & display values User Inputs Three programmable user inputs Max. Continuous Input: 30 VDC Isolation To Sensor Input Common: 1400 Vrms for 1 min. Working Voltage: 125 V Response Time: 50 msec. max. Logic State: Jumper selectable for sink/source logic Update Rates A/D conversion rate: 20 readings/sec. Step response: 1 sec max. to within 99% of final readout value (digital filter disabled) Display update rate: 1 to 20 updates/sec. Setpoint output on/off delay time: 0 to 3275 sec. Analog output update rate: 0 to 10 sec Max./Min. capture delay time: 0 to 3275 sec Max Crest Factor (Vp/VRMS): 5 @ Full Scale Input Input Coupling: AC or AC and DC Input Capacitance: 10 pF Common Mode Voltage: 125 VAC working Common Mode Rejection: (DC to 60 Hz) 100 dB Totalizer Time Base: second, minute, hour, or day Batch: Can accumulate (gate) input display from a user input Time Accuracy: 0.01% typical Decimal Point: 0 to 0.0000 Scale Factor: 0.001 to 65.000 Low Signal Cut-out: -19,999 to 99,999 Total: 9 digits, display alternates between high order and low order readouts Custom Linearization Data Point Pairs: Selectable from 2 to 16 Display Range: -19,999 to 99,999 Decimal Point: 0 to 0.0000 Standards Compliance CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A EN 61010-1: General Requirements EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component: File #E179259 UL Listed: File #E137808 Type 4X Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 60 C (-40 F to 140 F) Humidity: 85% max. relative humidity (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g. Shock to IEC 68-2-27: Operational 25 g (10 g relay). Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, IP20 Touch Safe, Installation Category II, Pollution Degree 2, One piece bezel/case; flame resistant; Synthetic rubber keypad; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max Dimensions: 1.95" x 3.8" x 4.2"
Communication options include RS232, RS485, Modbus, DeviceNet, and Profibus DP. A computer can remotely control the meter outputs if necessary. A separate option card also creates a linear DC output signal. The parameters can be completely locked after setup, or partially locked with only the setpoint values available.
|
|
|
|
|
|
|