The Red Lion PAXDP000 PAX series panel meter is a dual process input meter. It has a 5 digit, red LED display in a 1/8 DIN housing. This panel meter can accommodate two 4-20 mA or 0-10 VDC input signals, with the ability to scale and display each one separately. Math functions can also be applied to the two signals. Separate option cards provide alarms, comms, or retransmitted analog output for the meter. The meter's update rate can be chosen by the user. The range of 5 to 105 updates a second allows the user to adjust the settings for the application. AC powered
Features
- Dual Process Input
- 1/8 DIN Housing
- 5 Digit, Red LED Display
- Accommodates Two 4-20 mA or 0-10 VDC Input Signals
- Linearization/Square Root Extraction Input Range
- 9 Digit Totalizer (integrator) with Batching
- Programmable Function Keys/User Inputs
- 4 Setpoint Alarm Outputs (w/Option card)
- Communication & Bus Capabilities (w/Option card)
- Retransmitted Analog Output (w/Option card)
- 16 Bit Resolution A/D Converter
- 85 to 250 VAC Input
- NEMA 4X/IP65 - Front Panel
- Red LEDs Readable in Bright Sunlight
- Adjustable Brightness Can Fit Surrounding Conditions
Red Lion PAX DP Series User Manual
Specifications
Display 5 digit, 0.56" (14.2 mm) red sunlight readable LEDs, (-19999 to 99999) Annunciators: A, B, C, SP1 - setpoint alarm 1 active, SP2 - setpoint alarm 2 active, SP3 - setpoint alarm 3 active state, SP4 - setpoint alarm 4 active Power Requirements AC Power: 85 to 250 VAC, 50/60 Hz, 21 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. Memory Nonvolatile memory retains programmable parameters & display values User Inputs Three programmable user inputs Max. Continuous Input: 30 VDC Isolation To Sensor Input A Common: 500 Vrms for 1 min. Isolation To Sensor Input B Common: Not isolated. Response Time: 20 msec. max. Logic State: Jumper selectable for sink/source logic Update Rate A/D conversion rate: Adjustable 5.3 to 105 readings/sec. Step response: See User Manual Display update rate: adjustable 1 to 20 readings/sec. Setpoint output on/off delay time: 0 to 3275 sec. Analog output update rate: 0 to 10 sec Max./Min. capture delay time: 0 to 3275 sec Excitation Power Transmitter Power: 18 VDC, +/-20%, unregulated, 70 mA max. per
input channel.
Low Frequency Noise Rejection Normal Mode: See User Manual Common Mode: >100 dB @ 50/60 +/-1 Hz (19.8 or 20 Input Rate) Totalizer Time Base: second, minute, hour, or day Batch: Can accumulate (gate) input display from a user input Time Accuracy: 0.01% typical Decimal Point: 0 to 0.0000 Scale Factor: 0.001 to 65.000 Low Signal Cut-out: -19,999 to 99,999 Total: 9 digits, display alternates between high order and low order readouts Custom Linearization Data Point Pairs: Selectable from 2 to 16 Display Range: -19,999 to 99,999 Decimal Point: 0 to 0.0000 Standards Compliance CE Approved EN 61326-1 Immunity to Industrial Locations Emission EN 55011 Class A IEC/EN 61010-1 UL Recognized Component: File #E179259 UL Listed: File #E137808 Type 4X Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 60 C (-40 F to 140 F) Humidity: 85% max. relative humidity (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g. Shock to IEC 68-2-27: Operational 25 g (10 g relay). Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, IP20 Touch Safe, Installation Category II, Pollution Degree 2, One piece bezel/case; flame resistant; Synthetic rubber keypad; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. Dimensions: 1.95" x 3.8" x 4.2"
This panel meter features a MAX and MIN reading memory with a capture time that is programmable. The signal totalizer is used for calculating a time-input product or accumulate batch operations. Four setpoint outputs are provided by optional digital output cards. Option cards can also provide communication and bus capability. Modbus is the standard communication protocol, however RS232, RS485, DeviceNet and Profibus option cards can be used as well. A computer can also remotely control the meter's outputs if needed. An option card can also provide a linear DC output signal, with 20 mA or 10 V signals. The keypad has 5 function keys, with 3 of them being programmable. After setup the parameters can be completely locked, or with only the setpoint values available. This unit is not intended to directly command motors, valves or actuators without safeguards. Any option cards are all field upgradeable.
|
|
|
|
|
|
|