|
|
|
|
The Red Lion PAXCK100 PAX series panel meter is a timer with real-time clock capability. It has a 6 digit, green LED display in a 1/8 DIN housing. Communication and bus capabilities is done by option cards, which includes RS232, RS485, Modbus, DeviceNet, and Profibus-DP. AC powered. Switch contacts or CMOS & TTL circuit outputs are both examples of possible input sources. There are 5 function keys on the front panel; three are programmable to meet the needs of the application. Four setpoint outputs can be provided through the use of an optional digital output card.
Features
- 1/8 DIN Housing
- 6 Digit, Green LED Display
- Elapsed Timer w/Preset Capability
- Real-Time Clock
- 4 Displays- Timer, Clock, Date, Counter
- Cycle Counting Capability
- Programmable Function Keys/User Inputs
- 4 Setpoint Alarm Outputs (w/Option card)
- Communication & Bus Capability (w/Option card)
- Crimson Programming Software
- NEMA 4X/IP65 - Front Panel
- Parameters can be partially or completely locked after setup to avoid tampering
Red Lion PAX Series Timer User Manual
Specifications
Display 6 digit, 0.56" (14.2 mm) standard green LED Annunciators: TMR- Timer, CNT- Cycle Counter, DAT- Real time clock date or time SP1 - setpoint 1 output state, SP2 - setpoint 2 output state, SP3 - setpoint 3 output state, SP4 - setpoint 4 output state Power Requirements AC Power: 85 to 250 VAC, 50/60 Hz, 18 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. Sensor Power 12 VDC, +/-10%, 100 mA max. Short circuit protected Memory Nonvolatile E2PROM retains programmable parameters & display values User Inputs Three programmable user inputs Logic inputs configurable as Current Sinking (active low) or Current Sourcing (active high) through a single plug jumper. Current Sinking (active low): VIL = 0.9 V max., 22 KOhm pull-up to +12 VDC. Current Sourcing (active high): VIH = 3.6 V min., 22 KOhm pull-down, Max. Continuous Input: 30 VDC. Isolation To Timer Input Common: Not isolated Response Time: 10 msec Timer Display Timer Range: 23 Selectable Ranges Timing Accuracy: +/- 0.01% Minimum Digit Resolution: 0.001 Sec. Maximum Least Significant Digit Resolution: 1 Hr. Maximum Display: 999999 Real Time Display 5 display formats Hr/Min/Sec (12 or 24 Hr. format); Hr/Min (24 Hr.); Hr/Min (12 Hr. with or without AM/PM indication) Date Display: 7 display formats Month/Day or Day/Month (numeric or 3-letter Month format); Month/ Day/Year or Day/Month/Year (all numeric); Day of Week/Day (3-letter Day of Week format) Cycle Counter Display Counter Range: 0 to 999999 Digit Resolution: 1 cycle Maximum Count Rate: 50 Hz Timer Inputs A & B Logic inputs configurable as Current Sinking (active low) or Current Sourcing (active high) via a single plug jumper. Current Sinking (active low): VIL = 0.9 V max., 22 KOhm pull-up to +12 VDC. Current Sourcing (active high): VIH = 3.6 V min., 22 KOhm pull-down, Max. Continuous Input: 30 VDC. Timer Input Pulse Width: 1 msec min. Timer Start/Stop Response Time: 1 msec max. Filter: Software filtering provided for switch contact debounce. Filter enabled or disabled through programming. If enabled, filter results in 50 msec start/stop response time for successive pulses on the same input terminal Standards Compliance CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A EN 61010-1: General Requirements
EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component: File #E179259 UL Listed: File #E137808 Type 4X Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 60 C (-40 F to 140 F) Humidity: 85% max. relative humidity (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g.
Shock to IEC 68-2-27: Operational 25 g (10 g relay). Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, IP20 Touch Safe, Installation Category II, Pollution Degree 2, One piece bezel/case; flame resistant; Synthetic rubber keypad; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. Dimensions: 1.95" x 3.8" x 4.2"
This meter also works as an elapsed or preset timer as well as a clock, with both operations being in use at the same time. The display indicates four different parameters, including the timer, count, date, and real time clock. There are two inputs with 23 timing ranges, with the ability to be a dual or quad output timer through the use of an option card. When used as a clock, the time can be shown in 12 or 24 hour formatting. Either format can indicate hours and minutes, or hours, minutes, and seconds. The 12 hour format has the option to show AM or PM. When displaying the date, it can show the month, day, and year. Date or time changes for leap years or Daylight Savings Time are automatically configured. When using multiple PAXCK units, they have the ability to sync up with each other, so all meters can indicate the same time throughout the workplace. The battery operated time clock card will continue to show the current time even without the use of main power.
|
|
|
|
|
|
|