The Red Lion PAXCDL10 is an analog output option card. It is made for PAX series Red Lion panel meters. It can be configured for one of three ranges: 0-20 mA, 4-20 mA, or 0-10 VDC, and features 1/3500 resolution. Only one output range can be used at a given time. PAX series panel meters have slots for option cards in three different categories: serial communications, analog output, and setpoint output. The panel meter can only use one option card from each category.
Specifications
- Types- 0 to 20 mA, 4 to 20 mA and 0 to 10 VDC
- Isolation to Sensor & User Input Commons- 500 Vrms for 1 min.
Working Voltage: 50 V. Not isolated from all other commons.
- Accuracy- 0.17% of FS (18 to 28 C); 0.4% of FS (0 to 50 C)
- Resolution- 1/3500
- Compliance- 10 VDC: 10 KOhm load min.
20 mA: 500 Ohm load max. (self-powered)
- Update Time- 200 msec. max. to within 99% of final readout value (digital
filter and internal zero correction disabled)
700 msec. max. (digital filter disabled, internal zero correction enabled)
- For PAXH Panel Meters- Isolation To Sensor Common: 1400 Vrms for 1 min.
Working Voltage: 125 V
Isolation To User Input Common: 500 Vrms for 1 min.
Working Voltage: 50 V
Update Time: 1 sec. max. to within 99% of final readout value (digital filter disabled)
Red Lion PAX CDL Analog Option Card User Manual
Analog Output Option Card for PAX Series Panel Meters PAXCDL10