The Red Lion PAXC0120 PAX series panel meter is a dual counter with a 6 digit, green LED display in a 1/8 DIN housing. The display offers 0.56" numbers. Compatible inputs can come from sources such as switch contacts, CMOS & TTL circuit outputs, magnetic pickups, and RLC sensors. It accommodates directional, uni-directional, & Quadrature signals. The front panel has 5 keys, with 3 of them being programmable function keys. AC powered
Features
- 1/8 DIN Housing
- 6 Digit, Green LED Display
- Up to 3 Count Displays
- Programmable Scale Factors
- Programmable Function Keys/User Inputs
- Four Setpoint Alarm Outputs (w/ Option card)
- Dual Count Quad Inputs
- NEMA 4X/IP65 - Front Panel
- Adjustable Brightness Intensity to Fit Surrounding Conditions
Red Lion PAX Series User Manual
Specifications
Display 6 digit, 0.56" (14.2 mm) standard green LED Annunciators: A - Counter A, B - Counter B, C - Counter C - Upper significant digit display of counter SP1 - setpoint 1 output state, SP2 - setpoint 2 output state, SP3 - setpoint 3 output state, SP4 - setpoint 4 output state Power Requirements AC Power: 85 to 250 VAC, 50/60 Hz, 18 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working) Sensor Power 12 VDC, +/-10%, 100 mA max. Short circuit protected Memory Nonvolatile memory retains programmable parameters & display values User Inputs Three programmable user inputs Max. Continuous Input: 30 VDC Isolation To Sensor Input Commons: Not isolated Logic State: Jumper selectable for sink/source logic Response Time: 6 msec. typical; function dependent. Output Response Time: 25 microsec.; add 6 msec (typical) if a relay card is installed Timed Output Accuracy: Counter = +/- 0.01% + 10 msec. Standards Compliance CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A EN 61010-1: General Requirements
EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component: File #E179259 UL Listed: File #E137808 Type 4X Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 60 C (-40 F to 140 F) Humidity: 85% max. relative humidity (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g.
Shock to IEC 68-2-27: Operational 25 g (10 g relay). Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, IP20 Touch Safe, Installation Category II, Pollution Degree 2, One piece bezel/case; flame resistant; Synthetic rubber keypad; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. Dimensions: 1.95" x 3.8" x 4.2"
Four setpoint outputs can be provided for the meter through an optional digital output plug in card. The parameter list can be locked either completely, or with only the setpoints available after setup. This panel meter is perfect for use under the demanding conditions of the industrial environment. It should not be used to directly command motors, valves, and actuators without safeguards.
|
|
|
|
|
|
|