The Red Lion PAXC0030 PAX series panel meter is a dual counter with a 6 digit, Red LED display in a 1/8 DIN housing. The display offers 0.56" numbers, while the red LED is readable even in sunlight. Compatible inputs can come from switch contacts, CMOS & TTL circuit outputs, magnetic pickups, and RLC sensors. It accommodates directional, uni-directional, & Quadrature signals. The front panel has 5 keys, with 3 of them being programmable function keys. DC powered
Features
- 1/8 DIN Housing
- 6 Digit, Red LED Display
- Up to 3 Count Displays
- Programmable Scale Factors
- Programmable Function Keys/User Inputs
- Four Setpoint Alarm Outputs (w/ Option card)
- Dual Count Quad Inputs
- NEMA 4X/IP65 - Front Panel
- Adjustable Brightness to Fit Surrounding Environment
Red Lion PAX Series User Manual
Specifications
Display 6 digit, 0.56" (14.2 mm) red sunlight readable LED Annunciators: A - Counter A, B - Counter B, C - Counter C - Upper significant digit display of counter SP1 - setpoint 1 output state, SP2 - setpoint 2 output state, SP3 - setpoint 3 output state, SP4 - setpoint 4 output state Power Requirements DC Power: 11 to 36 VDC, 14 W (derate operating temperature to 40 C if operating <15 VDC and three plug-in option cards are installed)
AC Power: 24 VAC, +/-10%, 50/60 Hz, 15 VA
Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working). Sensor Power 12 VDC, +/-10%, 100 mA max. Short circuit protected Memory Nonvolatile memory retains programmable parameters & display values User Inputs Three programmable user inputs Max. Continuous Input: 30 VDC Isolation To Sensor Input Commons: Not isolated Logic State: Jumper selectable for sink/source logic Response Time: 6 msec. typical; function dependent. Output Response Time: 25 microsec.; add 6 msec (typical) if a relay card is installed Timed Output Accuracy: Counter = +/- 0.01% + 10 msec. Standards Compliance CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A EN 61010-1: General Requirements
EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component: File #E179259 UL Listed: File #E137808 Type 4X Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 60 C (-40 F to 140 F) Humidity: 85% max. relative humidity (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g.
Shock to IEC 68-2-27: Operational 25 g (10 g relay). Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, IP20 Touch Safe, Installation Category II, Pollution Degree 2, One piece bezel/case; flame resistant; Synthetic rubber keypad; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. Dimensions: 1.95" x 3.8" x 4.2"
Four setpoint outputs can be supplied for the meter through an optional digital output plug in card. After setup, the parameter list can be locked either completely, or with only the setpoints available. This panel meter proves ideal for use in industrial applications. The meter should not be used to directly command motors, valves, and actuators without safeguards.
|
|
|
|
|
|
|