Home > Panel Meters > C48 1/16 DIN Counters & Timers >

Red Lion Panel Meter, Single Preset Timer, AC, NPN OC/Relay Output


Red Lion C48TS003 Panel Meter, Single Preset Timer
Red Lion C48TS003 Panel Meter, Single Preset Timer, AC, NPN OC/Relay Output
 
Alternative Views:


Price: $252.00
Note: Please call or email [email protected] for alternatives
MFG P/N: C48TS003
MFG: Red Lion
Weight (lbs): 0.38

Quantity in Stock :(Out of Stock)


Availability:
Out of Stock
Product Code: C48TS003
Qty:

Description
 

The Red Lion C48TS003 C48 series panel meter is a single preset timer with an NPN OC / relay output. It features a 2 line, 6 digit, reflective LCD display with 1/16 DIN housing. The reflective display shows positive lit numbers on a negative background. The resistance to noise interference makes it perfect for industrial areas. AC powered. Note: This timer is not recommended for directly controlling motors, valves, or actuators that do not have safeguards.

Features

  • One Preset
  • 12 Timing Range Modes
  • Dual Line, 6 Digit Reflective LCD Display
  • NPN OC/Relay Output
  • 85 to 250 VAC Input Power
  • NEMA 4X/IP65 - Front Panel
  • Field Replaceable Relay Output Board
  • Status Indicators for Outputs
  • Programmable User Inputs
  • Function Keys on Front Panel
  • Black Plastic Housing is Lightweight & Withstands Impact
  • Can be Stacked Together Horizontally or Vertically

Red Lion C48T Series User Manual

Specifications

Display
Main Display: 0.3" digits
Secondary Display: 0.2" digits
Annunciators: Value- PRS, 1, & 2; Output- 01 and 02
Power Requirements
AC Power: 85-250 VAC, 50/60 Hz, 9 VA max
DC Power: 11-14 VDC @ 150 mA max
Memory
Nonvolatile E2PROM retains all programmable parameters and timer values
Sensor Power
+12 VDC (+/- 15%) @100 mA max
Count Inputs A & B
Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC
Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max
Debounce: 50 Hz max
Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min.
Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min
User Inputs
Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC
Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown
Run/Stop Response Time: 250 usec max.
User Input Response Time: 5 msec max.
Time Accuracy: +/- 0.01%
Outputs
Solid State: NPN Open Collector- ISNK = 100 mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max.
Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load)
Relay Life Expectancy: 100,000 cycles min. at max. load rating
Standards Compliance
UL & CUL Recognized
Electrostatic Discharge: EN 61000-4-2
Electromagnetic RF Fields: EN 61000-4-3
Fast Transients (burst): EN 61000-4-4
RF Conducted Interference: EN 61000-4-6
Simulation of Cordless Phone: ENV 50204
RF Interference: EN 55011
Physical
Operating Temperature: 0 C to 50 C (32 F to 122 F)
Storage Temperature: -40 C to 70 C (-40 F to 158 F)
Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C.
Altitude: Up to 2000 meters
Housing: Black Plastic
Electrical Connection: Wire clamping screw terminals
Dimensions: 1.95" x 1.95" x 4.54"

This timer features 18 operating modes & 12 timing ranges, measuring from thousandths of a second up to minutes and hours. Timing can be programmed to constantly accumulate or reset with each power cycle. Timing units (seconds, minutes, hours) are separated on the display with decimal points. It accommodates On Delay, Off Delay, Single Shot, & Repetitive Auto Cycling timing modes. It has a Run/Stop Input, and three programmable User Inputs. The buttons on the front operate programming modes & data values, changing the display, and resetting. Numerical data entry is done through digit entry or automatic scrolling. Run/Stop and User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. The NPN OC solid state and relay output operates in parallel. The relay output boards are all field replaceable.

Panel Meter Comparison Chart