The Red Lion C48TD117 C48 series panel meter is a dual preset timer with dual relay outputs. It has a 2 line, 6 digit, transmissive backlit LCD display with 1/16 DIN housing. The backlit display has a red readout on the main line and a green readout on the second line. The resistance to noise interference makes it perfect for industrial use. DC powered. Note: This timer is not intended for directly controlling motors, valves, or actuators that do not have safeguards.
Features
- Two Presets
- 12 Timing Range Modes
- Dual Line, 6 Digit Transmissive LCD Display w/Backlighting
- Red Top Line & Green Lower Line
- Dual Relay Outputs
- 18 to 36 VDC (24 VDC nominal) Input Power
- NEMA 4X/IP65 - Front Panel
- RS-485 Communications Capability
- Field Replaceable Relay Output Boards
- Status Indicators for Outputs
- Programmable User Inputs
- Function Keys on Front Panel
- Lightweight Black Plastic Casing Withstands Impact
- Can be Stacked Together Horizontally or Vertically
Red Lion C48T Series User Manual
Specifications
Display Main Display: 0.3" digits Secondary Display: 0.2" digits Annunciators: Value- PRS, 1, & 2; Output- 01 and 02 Power Requirements DC Power: 18-36 VDC, 5.5 W max. AC Power: 24 VAC +/- 10%; 50/60 Hz; 7 VA max. Memory Nonvolatile E2PROM retains all programmable parameters and timer values Sensor Power +12 VDC (+/- 15%) @100 mA max Count Inputs A & B Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max Debounce: 50 Hz max Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min. Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min User Inputs Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown Run/Stop Response Time: 250 usec max. User Input Response Time: 5 msec max. Time Accuracy: +/- 0.01% Outputs Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load) Relay Life Expectancy: 100,000 cycles min. at max. load rating Standards Compliance UL & CUL Recognized Electrostatic Discharge: EN 61000-4-2 Electromagnetic RF Fields: EN 61000-4-3 Fast Transients (burst): EN 61000-4-4 RF Conducted Interference: EN 61000-4-6 Simulation of Cordless Phone: ENV 50204 RF Interference: EN 55011 Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 70 C (-40 F to 158 F) Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C. Altitude: Up to 2000 meters Housing: Black Plastic Electrical Connection: Wire clamping screw terminals Dimensions: 1.95" x 1.95" x 4.54" RS-485 Serial Communications Baud Rate: Programmable from 1200 to 9600 baud Address: Programmable from 0 to 99 Data Format: 10 Bit Frame, 1 start bit, 7 or 8 data bits, 1 or No Parity bit, & 1 stop bit Parity: Programmable for Odd (7 data bits), Even (7 data bits), or None (8 data bits)
The timer includes 42 operating modes & 12 timing ranges, measuring from thousandths of a second up to minutes and hours. Timing can be set to constantly accumulate or reset with each power cycle. Decimal points separate the timing units (seconds, minutes, hours) on the display. It accommodates On Delay, Off Delay, Single Shot, & Repetitive Auto Cycling timing modes. It features a Run/Stop Input, and three programmable User Inputs. The push buttons on the front control programming modes & data values, changing the display, and resetting. Numerical data entry is achieved through digit entry or automatic scrolling. Run/Stop and User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. Relay output boards are field replaceable. The RS-485 serial communication interface makes it possible for two way communication with a printer, computer, or other device.
|
|
|
|
|
|
|