The Red Lion C48CD107 C48 series panel meter is a standard dual preset counter with dual relay outputs. It has a 2 line, 6 digit, transmissive LCD display with backlighting and a 1/16 DIN housing. The backlit display has a red digital readout on the main line and a green readout on the second line. It withstands noise interference, making it ideal for industrial applications. AC powered.
Features
- Two Presets
- Bi-directional & Quadrature Counting
- Dual Line, 6 Digit Transmissive LCD Display w/Backlighting
- Red Top Line & Green Lower Line
- Dual Relay Outputs
- Up to 11KHz
- NEMA 4X/IP65 - Front Panel
- RS-485 Communications Capability
- Field Replaceable Relay Output Boards
- Status Indicators for Outputs
- Programmable User Inputs
- Function Keys on Front Panel
- Lightweight Housing Resists Impact
- Several Can be Stacked Horizontally or Vertically
Red Lion C48C Series User Manual
Specifications
Display Main Display: 0.3" digits Secondary Display: 0.2" digits Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03 Power Requirements AC Power: 85-250 VAC, 50/60 Hz, 9 VA max DC Power: 11-14 VDC @ 150 mA max Memory Nonvolatile E2PROM retains all programmable parameters and count values Sensor Power +12 VDC (+/- 15%) @100 mA max Count Inputs A & B Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max Debounce: 50 Hz max Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min. Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min User Inputs Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown Response Time: 10 msec max. Inhibit Response Time: 250 usec max. Outputs Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load) Relay Life Expectancy: 100,000 cycles min. at max. load rating Standards Compliance UL & CUL Recognized Electrostatic Discharge: EN 61000-4-2 Electromagnetic RF Fields: EN 61000-4-3 Fast Transients (burst): EN 61000-4-4 RF Conducted Interference: EN 61000-4-6 Simulation of Cordless Phone: ENV 50204 RF Interference: EN 55011 Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 70 C (-40 F to 158 F) Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C. Altitude: Up to 2000 meters Housing: Black Plastic Electrical Connection: Wire clamping screw terminals Dimensions: 1.95" x 1.95" x 4.54" RS-485 Serial Communications Baud Rate: Programmable from 1200 to 9600 baud Address: Programmable from 0 to 99 Data Format: 10 Bit Frame, 1 start bit, 7 or 8 data bits, 1 or No Parity bit, & 1 stop bit Parity: Programmable for Odd (7 data bits), Even (7 data bits), or None (8 data bits)
The unit has nine programmable counting modes, and can be programmed to register counts on both edges of the input signal. Programming modes & data values, changing the display, and resetting is accomplished by the push buttons on the front. Data entry is done by digit entry or automatic scrolling. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. The relay outputs are activated through presets 1 and 2. Relay output boards are field replaceable. The RS-485 serial communication interface allows for two way communication with a printer, computer, or other device.
|
|
|
|
|
|
|