|
|
|
|
The Red Lion C48CD100 C48 series panel meter is a standard dual preset counter with dual NPN OC outputs. It has a 2 line, 6 digit, transmissive LCD display with backlighting and a 1/16 DIN housing. The backlit display shows a red digital readout on the main line and a green readout on the secondary line. It resists noise interference, making it perfect for industrial applications. AC powered.
Features
- Two Presets
- Bi-directional & Quadrature Counting
- Dual Line, 6 Digit Transmissive LCD Display w/Backlighting
- Red Top Line & Green Lower Line
- Dual NPN OC Outputs
- Up to 11KHz
- NEMA 4X/IP65 - Front Panel
- Status Indicators for Outputs
- Programmable User Inputs
- Function Keys on Front Panel
- Lightweight Housing Withstands Impact
- Can be Stacked Horizontally or Vertically
Red Lion C48C Series User Manual
Specifications
Display Main Display: 0.3" digits Secondary Display: 0.2" digits Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03 Power Requirements AC Power: 85-250 VAC, 50/60 Hz, 9 VA max DC Power: 11-14 VDC @ 150 mA max Memory Nonvolatile E2PROM retains all programmable parameters and count values Sensor Power +12 VDC (+/- 15%) @100 mA max Count Inputs A & B Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max Debounce: 50 Hz max Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min. Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min User Inputs Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown Response Time: 10 msec max. Inhibit Response Time: 250 usec max. Outputs Solid State: NPN Open Collector- ISNK = 100 mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max. Standards Compliance UL & CUL Recognized Electrostatic Discharge: EN 61000-4-2 Electromagnetic RF Fields: EN 61000-4-3 Fast Transients (burst): EN 61000-4-4 RF Conducted Interference: EN 61000-4-6 Simulation of Cordless Phone: ENV 50204 RF Interference: EN 55011 Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 70 C (-40 F to 158 F) Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C. Altitude: Up to 2000 meters Housing: Black Plastic Electrical Connection: Wire clamping screw terminals Dimensions: 1.95" x 1.95" x 4.54"
Featuring nine programmable counting modes, the panel meter can be programmed to register counts on both edges of the input signal. Programming modes & data values, changing the display, and resetting is done through the function keys located on the front. Data entry is achieved through digit entry or automatic scrolling. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. The NPN open collector solid state outputs are activated through presets 1 and 2.
|
|
|
|
|
|
|