The Red Lion C48CD007 C48 series panel meter is a standard dual preset counter with dual relay outputs. It features a 2 line, 6 digit, reflective LCD display with 1/16 DIN housing. The reflective display has positive lit numbers on a negative background. It withstands noise interference, making it perfect for industrial use. AC powered.
Features
- Two Presets
- Bi-directional & Quadrature Counting
- Dual Line, 6 Digit Reflective LCD Display
- Dual Relay Outputs
- Up to 11KHz
- NEMA 4X/IP65 - Front Panel
- RS-485 Communication Capability
- Field Replaceable Relay Output Board
- Status Indicators for Outputs
- Programmable User Inputs
- Function Keys on Front Panel
- Lightweight Housing Resistant to Impact
- Can be Stacked Horizontally or Vertically
Red Lion C48C Series User Manual
Specifications
Display Main Display: 0.3" digits Secondary Display: 0.2" digits Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03 Power Requirements AC Power: 85-250 VAC, 50/60 Hz, 9 VA max DC Power: 11-14 VDC @ 150 mA max Memory Nonvolatile E2PROM retains all programmable parameters and count values Sensor Power +12 VDC (+/- 15%) @100 mA max Count Inputs A & B Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max Debounce: 50 Hz max Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min. Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min User Inputs Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown Response Time: 10 msec max. Inhibit Response Time: 250 usec max. Outputs Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load) Relay Life Expectancy: 100,000 cycles min. at max. load rating Standards Compliance UL & CUL Recognized Electrostatic Discharge: EN 61000-4-2 Electromagnetic RF Fields: EN 61000-4-3 Fast Transients (burst): EN 61000-4-4 RF Conducted Interference: EN 61000-4-6 Simulation of Cordless Phone: ENV 50204 RF Interference: EN 55011 Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 70 C (-40 F to 158 F) Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C. Altitude: Up to 2000 meters Housing: Black Plastic Electrical Connection: Wire clamping screw terminals Dimensions: 1.95" x 1.95" x 4.54" RS-485 Serial Communications Baud Rate: Programmable from 1200 to 9600 baud Address: Programmable from 0 to 99 Data Format: 10 Bit Frame, 1 start bit, 7 or 8 data bits, 1 or No Parity bit, & 1 stop bit Parity: Programmable for Odd (7 data bits), Even (7 data bits), or None (8 data bits)
The panel meter features nine programmable counting modes & can be programmed to register counts on both edges of the input signal. Operations such as programming modes & data values, changing the display, and resetting is done with the buttons located on the front. Numeric data entry is configured through digit entry or automatic scrolling. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. The relay outputs are activated through presets 1 and 2. Relay output boards are all field replaceable. Two way communication with a printer, computer, or other device can be achieved through the RS-485 serial communication interface.
|
|
|
|
|
|
|