The Red Lion C48CB108 C48 series panel meter is a batch counter with 1 NPN OC & 2 relay outputs. It features a 2 line, 6 digit, transmissive LCD display with backlighting and a 1/16 DIN housing. The main process counter has dual presets and the secondary counter has one preset. The secondary counter is utilized as a batch or total counter. The backlit display shows a red readout on the main line and a green readout on the secondary line. The resistance to noise interference makes it perfect for industrial use. AC powered.
Features
- Three Presets
- Bi-directional & Quadrature Counting
- Dual Line, 6 Digit Transmissive LCD Display w/Backlighting
- Red Top Line & Green Lower Line
- 1 NPN OC / 2 Relay Outputs
- Up to 11KHz
- NEMA 4X/IP65 - Front Panel
- RS-485 Communications Capability
- Field Replaceable Relay Output Board
- Status Indicators for Outputs
- Programmable User Inputs
- Function Keys on Front Panel
- Lightweight Housing Stands Up to Impact
- Several Can be Stacked Horizontally or Vertically
Red Lion C48C Series User Manual
Specifications
Display Main Display: 0.3" digits Secondary Display: 0.2" digits Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03 Power Requirements AC Power: 85-250 VAC, 50/60 Hz, 9 VA max DC Power: 11-14 VDC @ 150 mA max Memory Nonvolatile E2PROM retains all programmable parameters and count values Sensor Power +12 VDC (+/- 15%) @100 mA max Count Inputs A & B Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max Debounce: 50 Hz max Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min. Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min User Inputs Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown Response Time: 10 msec max. Inhibit Response Time: 250 usec max. Outputs Solid State: NPN Open Collector- ISNK = 100 mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max. Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load) Relay Life Expectancy: 100,000 cycles min. at max. load rating Standards Compliance UL & CUL Recognized Electrostatic Discharge: EN 61000-4-2 Electromagnetic RF Fields: EN 61000-4-3 Fast Transients (burst): EN 61000-4-4 RF Conducted Interference: EN 61000-4-6 Simulation of Cordless Phone: ENV 50204 RF Interference: EN 55011 Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 70 C (-40 F to 158 F) Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C. Altitude: Up to 2000 meters Housing: Black Plastic Electrical Connection: Wire clamping screw terminals Dimensions: 1.95" x 1.95" x 4.54" RS-485 Serial Communications Baud Rate: Programmable from 1200 to 9600 baud Address: Programmable from 0 to 99 Data Format: 10 Bit Frame, 1 start bit, 7 or 8 data bits, 1 or No Parity bit, & 1 stop bit Parity: Programmable for Odd (7 data bits), Even (7 data bits), or None (8 data bits)
There are nine programmable counting modes & the unit can be programmed to register counts on both edges of the input signal. Programming modes & data values, changing the display, and resetting functions can all be done through the buttons on the front. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. It features relay outputs for Output 2 and Output 3. Output 1 is a solid-state NPN current sinking, open collector output. Output 1 and Output 2 are for the primary process counter, while Output 3 is for the secondary batch or total counter. Two way communication with a printer, computer, or other device is possible with the RS-485 serial communication interface.
|
|
|
|
|
|
|