Description
 

The Red Lion C48CB100 C48 series panel meter is a batch counter with 3 NPN OC outputs. It features a 2 line, 6 digit, transmissive LCD display with backlighting and a 1/16 DIN housing. It has a main process counter with dual presets and a second counter with one preset. The second counter is used as a batch or total counter. The backlit display shows a red digital readout on the main line and a green readout on the secondary line. It also resists noise interference, making it perfect for industrial use. AC powered.

Features

  • Three Presets
  • Bi-directional & Quadrature Counting
  • Dual Line, 6 Digit Transmissive LCD Display w/Backlighting
  • Red Top Line & Green Lower Line
  • 3 NPN OC Outputs
  • Up to 11KHz
  • NEMA 4X/IP65 - Front Panel
  • Status Indicators for Outputs
  • Programmable User Inputs
  • Function Keys on Front Panel
  • Lightweight Housing Withstands Impact
  • Can Be Stacked Horizontally or Vertically

Red Lion C48C Series User Manual

Specifications

Display
Main Display: 0.3" digits
Secondary Display: 0.2" digits
Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03
Power Requirements
AC Power: 85-250 VAC, 50/60 Hz, 9 VA max
DC Power: 11-14 VDC @ 150 mA max
Memory
Nonvolatile E2PROM retains all programmable parameters and count values
Sensor Power
+12 VDC (+/- 15%) @100 mA max
Count Inputs A & B
Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC
Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max
Debounce: 50 Hz max
Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min.
Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min
User Inputs
Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC
Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown
Response Time: 10 msec max.
Inhibit Response Time: 250 usec max.
Outputs
Solid State: NPN Open Collector- ISNK = 100 mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max.
Standards Compliance
UL & CUL Recognized
Electrostatic Discharge: EN 61000-4-2
Electromagnetic RF Fields: EN 61000-4-3
Fast Transients (burst): EN 61000-4-4
RF Conducted Interference: EN 61000-4-6
Simulation of Cordless Phone: ENV 50204
RF Interference: EN 55011
Physical
Operating Temperature: 0 C to 50 C (32 F to 122 F)
Storage Temperature: -40 C to 70 C (-40 F to 158 F)
Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C.
Altitude: Up to 2000 meters
Housing: Black Plastic
Electrical Connection: Wire clamping screw terminals
Dimensions: 1.95" x 1.95" x 4.54"

There are nine programmable counting modes & the unit can be programmed to register counts on both edges of the input signal. Functions such as programming modes & data values, changing the display, and resetting can all be done through the push buttons located on the front. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. It features three solid-state NPN current sinking, open collector outputs. Output 1 and Output 2 are for the primary process counter, while Output 3 is for the secondary batch or total counter.