Physical Height: 5.7"
Width: 2.25"
Depth: 4.83"
Weight: 1.63 pounds
Electrical Input Voltage: 10-49V DC
Steady Input Range: 0.52 A @ 24 VDC
BTU/hr: 42.58
Environmental
Operating Temperature: -40 C to 80 C (-40 F to 176 F)
Storage Temperature: -40 C to 85 C (-40 F to 185 F)
Operating Humidity: 10% to 95% Relative Humidity (Non Condensing)
Operating Altitude: 0 to 10,000 ft.
Network Media 10BaseT: >/= Cat3 Cable
100BaseTX: >/= Cat5 Cable
1000BaseT: >/= Cat5e Cable
100BaseFX Multimode: 50-62.5/125μm
Connectors 10/100/1000BaseT: (16) RJ45 Copper Ports
100BaseFX: (2) ST 2 KM Duplex Fiber Ports
Recommended Min Wiring ClearanceFront: 4"
Top: 4"
ManagementWeb interface (Configuration wizard & graphical dashboard)
Command Line Interface
Port control
IGMP v1/v2/v3 auto-configuration
SNMP v1/v2/v3
NTP
802.1Q tag VLAN and port VLAN
IEEE 802.1p QoS and port QoS
DHCP client
Text-based configuration file
File transfer: HTTP/HTTPS, TFTP, SNMP
SecuritySSH, SSL, HTTPS
MAC Filtering
IEEE 802.1X with RADIUS remote server authentication
Port/User lockout after failed authentication attempts
SNMPv3
Password encryption
DiagnosticPort mirroring
Event log/Syslog
LLDP
Advanced cable diagnostics
Network RedundancyRSTP/MSTP
Port trunking/LACP
N-Ring™ auto-member
MIBsRFC 2674 VLAN MIBRFC 2819 RMON (Group 1, 2, 3 & 9)
RFC 1213 MIB II
RFC 1215 TRAPS MIB
RFC 4188 Bridge MIB
RFC 4292 IP Forwarding Table MIB
RFC 4293 Management Information Base for the Internet Protocol (IP)
RFC 5519 Multicast Group Membership Discovery MIB
RFC 2863 Interface Group MIB using SMI v2
RFC 4133 Entity MIB version 3
RFC 3411 SNMP Management Frameworks
RFC 3414 User-based Security Model for SNMPv3
RFC 3415 View-based access Control Model for SNMP
IEEE 802.1AB LLDP-MIB
IEEE 802.1 MSTP MIB
Certification & Compliance
Product Safety: UL 61010 and C22.2 No. 61010 OrdLoc, UL 121201 and CSA C22.2 No. 213 Class I, Division 2 HazLoc, ATEX, IECEx and UKEx II 3 G Ex ec nC IIC T4 Gc, UL 20 ATEX 2645X, UL 22.0038X IECEx and UL22UKEX2346X
EMI/EMC: CFR 47, Part 15, Subpart B, Canada ICES-003, ANSI C63.4, EN 61000-6-2 and 4, IEC 61000-4-2, 3, 4, 5, 6 and 8
Shock & Vibration (panel mounted) - IEC 68-2-27: 200 g @ 10 ms Triaxial; non-operational, IEC 68-2-6: 15 g @ 5-200 Hz Triaxial; operational
Railway/Rolling Stock - EN 50155, EN 50121 and EN 61373
Marine: ABS Type Approval for Shipboard Applications DNV (pending)
Designed to Comply With - IEEE 1613 for Electric Utility Substations and NEMA TS1/TS2 for Traffic Control
Other – RoHS compliant