Home > Industrial Ethernet Switches > Power Supplies & Routers >

Autonics Switching Mode Power Supply, 50W, 24VDC

Autonics SPA-050-24 Switching Mode Power Supply
Autonics SPA-050-24 Switching Mode Power Supply, 50W, 24VDC
 
Alternative Views:


Price: $119.25
Note: Call 800-966-2345 for Lead Time
MFG P/N: SPA-050-24
MFG: Autonics
Weight (lbs): 0.8



Availability:
In Stock
Product Code: SPA-050-24
Qty:

Description
 

The Autonics SPA-050-24 is a switching mode Power Supply that can be used to change 100-240V AC input to 24V DC output. It is 2.1 Amp and 50 watts at 24 VDC. This power supply features several circuit protections, including over-current, inrush current, and short circuit. A green LED light indicates the output status. Note: Image is for reference, actual part may differ

Specifications

  • Dimensions- 3.82" Width x 4.72" Length x 1.57" Height
  • Output Power- 50W
  • Output Voltage- 24V DC
  • Input Voltage- 100-240V AC
  • Input Frequency- 50/60 Hz
  • Input Efficiency- Min 80%
  • Input Current- Max 1.1 Amps
  • Output Current- 2.1 Amps
  • Voltage Adjustment Range- +/- 5%
  • Input Variation- Max +/- 0.5%
  • Load Variation- Max +/- 1%
  • Ripple- Max +/- 1%
  • Start Up Time- Max 150 milliseconds
  • Hold Time- Min 10 milliseconds
  • Inrush Current Protection- Max 20 Amps (100VAC)
  • Over Current Protection- Min 110%
  • Output Short Circuit Protection- Max 5 milliseconds
  • Insulation Resistance- Over 100 MOhm
  • Dielectric Strength- 3000VAC 5060 Hz for 1 min (between input & output terminals), 1500VAC 50/60 Hz for 1 min (between input terminals & F.G.)
  • Vibration- 0.75mm amplitude at frequency of 10 to 55hz (for 1 min) in each X, Y, Z direction for 2 hours
  • Shock- 300m/s2 (approx 30G) in each X, Y, Z direction for 3 times
  • Electromagnetic Susceptibility- EN61000-6-2
  • Electromagnetic Interference- EN61000-6-4
  • Safety Standards- EN60950, EN50178
  • Ambient Temperature- 14 F to 122 F
  • Storage Temperature- -13 F to 149 F
  • Ambient Humidity- 25 to 85% Relative Humidity
  • Storage Humidity- 25 to 90% Relative Humidity
  • Tightening Torque- 0.7 to 0.9 Nm
  • Approvals- CE