Home > Panel Meters > PAX Lite 1/8 DIN Panel Meters >

Red Lion AC Volt Panel Meter


Red Lion AC Volt Panel Meter
Red Lion PAXLVA00 AC Volt Panel Meter
 
Alternative Views:


Price: $221.00
MFG P/N: PAXLVA00
MFG: Red Lion
Weight (lbs): 0.65

Quantity in Stock :2


Availability:
In Stock
Product Code: PAXLVA00
Qty:

Description
 

The Red Lion PAXLVA00 PAX LV Lite series AC volt panel meter has a 3 1/2 digit, red LED display in a 1/8 DIN housing. It features selectable AC voltage ranges, built-in scaling provisions, and selectable decimal points. It uses variables that can be displayed as a voltage, such as readouts from pressure, speed, or flow transducers. The display can show a minus sign if the voltage is in the negative. AC powered.

Features

  • Selectable AC Voltage Ranges:
  • 0 to 1.999 V, 0 to 19.99 V, 0 to 199.9 V, 0 to 300 V
  • 1/8 DIN Housing
  • 3 1/2 Digit, Red LED Display w/Polarity
  • Built In Scaling Provisions
  • Selectable Decimal Point Location
  • Auto Zeroing Circuits
  • Over-Range Indication
  • NEMA 4X/IP65 - Front Panel

Red Lion PAX LI Lite Series User Manual

Specifications

Display
3 1/2 digit, 0.56" (14.2 mm) red LEDs
Power Requirements
115 or 230 VAC, switch selectable. Allowable power line variation
+/-10%, 50/60 Hz, 6 VA.
Isolation: 2300 Vrms for 1 min. between input and supply
Working Voltage: 300 V max., CAT II
Accuracy
+/-(.1% of Reading + 3 digits) (45-500 Hz)
Max Voltage on Lowest Input Range: 75 VAC or DC
Max Voltage on Terminal Block: 300 VAC or DC
Response Time to Step Change Input: 1 sec. nominal
Reading Rate: 2.5 readings/sec., nominal
Common Mode Voltage (Comm to Earth): 350 volt peak
Temperature Coefficents: +/-150 PPM/°C
Standards Compliance
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report # 04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Electromagnetic Compatibility: See user manual
Physical
Operating Temperature: 0 C to 60 C (32 F to 140 F)
Storage Temperature: -40 C to 80 C (-40 F to 176 F)
Humidity: 85% max. relative humidity (non-condensing)
Vibration to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2 g's.
Shock to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions
Altitude: Up to 2000 meters
Construction: NEMA 4X/IP65 outdoor use, Installation Category II, Pollution Degree 2,
One piece bezel/case; flame resistant; panel gasket & mounting clip
Connection: High Compression Cage-Clamp Terminal Block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
Dimensions: 1.95" x 3.8" x 4.2"

Panel Meter Comparison Chart