Home > Panel Meters > PAX Lite 1/8 DIN Panel Meters >

Red Lion AC Current Panel Meter


Red Lion AC Current Panel Meter
Red Lion PAXLIA00 AC Current Panel Meter
 
Alternative Views:


Price: $221.00
Note: Call 800-966-2345 for Lead Time
MFG P/N: PAXLIA00
MFG: Red Lion
Weight (lbs): 0.65



Availability:
In Stock
Product Code: PAXLIA00
Qty:

Description
 

The Red Lion PAXLIA00 PAX LI Lite series AC current panel meter has a 3 1/2 digit, red LED display in a 1/8 DIN housing. It features selectable AC current ranges, built-in scaling provisions, and selectable decimal points. It uses variables that can be displayed as a current readout, such as readouts from pressure, speed, or flow transducers. The display can show a minus sign if the current is in the negative. AC powered. Accessory shunts are available for higher current ranges.

Features

  • Selectable AC Current Ranges:
  • 0 to 199.9uA/199.9mV, 0 to 1.999mA, 0 to 19.99mA, 0 to 199.9mA, 0 to 1.999A
  • 1/8 DIN Housing
  • 3 1/2 Digit, Red LED Display w/Polarity
  • Built In Scaling Provisions
  • Selectable Decimal Point Location
  • Auto Zeroing Circuits
  • Over-Range Indication
  • NEMA 4X/IP65 - Front Panel

Red Lion PAX LI Lite Series User Manual

Specifications

Display
3 1/2 digit, 0.56" (14.2 mm) red LEDs
Power Requirements
115 or 230 VAC, switch selectable. Allowable power line variation
+/-10%, 50/60 Hz, 6 VA.
Isolation: 2300 Vrms for 1 min. between input and supply
Working Voltage: 300 V max., CAT II
Accuracy
(45-500 Hz)
199.9 µA/199.9 mV, 1.999 mA, 19.99 mA: +/-(0.1% of Reading + 3 digits)
199.9 mA: +/-(0.15% of Reading + 3 digits)
1 A: +/-(0.5% of Reading + 3 digits)
Max Voltage on Lowest Input Range: 75 VAC or DC
Max Voltage on Terminal Block: 300 VAC or DC
Response Time to Step Change Input: 1 sec. nominal
Reading Rate: 2.5 readings/sec., nominal
Common Mode Voltage (Comm to Earth): 350 volt peak
Max Currents
199.9 uA through 19.99 mA: 10 times max. range current
199.9 mA: 1 A
1.999 A: 3 A
Standards Compliance
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report # 04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Electromagnetic Compatibility: See user manual
Physical
Operating Temperature: 0 C to 60 C (32 F to 140 F)
Storage Temperature: -40 C to 80 C (-40 F to 176 F)
Humidity: 85% max. relative humidity (non-condensing)
Vibration to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2 g's.
Shock to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions
Altitude: Up to 2000 meters
Construction: NEMA 4X/IP65 outdoor use, Installation Category II, Pollution Degree 2,
One piece bezel/case; flame resistant; panel gasket & mounting clip
Connection: High Compression Cage-Clamp Terminal Block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
Dimensions: 1.95" x 3.8" x 4.2"

Panel Meter Comparison Chart