The Lumberg Automation 934692001 0980 ESL 801 Lion-R is an active 8 port 5 pin M12 distribution block, with 16 digital inputs. Has LED indicators to show the current status and two 7/8" power supply ports. It is a Profinet device, made to operate under more extreme conditions and create secure communication of data. Rated IP 67.
Features
- Galvanic isolation between sensors/actuators and Profinet
- Less time required to find a fault
- "Fail safe" function promotes reliability & switches the module off if a fault is found
- Support for RT and IRT in real time standards
- Multiple M12 connections reduce time and cost, while making it easy to expand
- Integrated 10/100 Mbs dual port switch for line topologies
- 7/8" power supply & M12 ports support T distributors
- Vibration resistant
- Overall mechanical stability and functional reliability
- PNO certification
TECHNICAL DATA
- Protection Class- IP 67
- Operating Temperature Range- -10 C to 60 C (14 F to 140 F)
- Housing Material- Diecast Zinc
- Dimensions- 261.4mm Length x 59.6mm Width x 17.6mm Height (10.3" x 2.35" x 0.7")
BUS SYSTEM
- Transmission Rate- 10/100 Mbs
- Address Range- 0-255 (default address 0)
INPUTS
- Rated Voltage- 24 VDC
- Sensor Type- PNP (source)
- Power Consumption of Sensor- Max. 100 mA
- Reverse Polarity Protection- Yes
- Short Circuit Proof- Yes
- Number of Digital Channels- 16
- Status Indicator- LED white per channel
- Diagnostic Indicator- LED red per port
- Approvals- UL, CSA
Diagnostic Information
|
LED
|
Indication
|
Condition
|
Us
|
Green
|
Logic/sensor power supply
|
UL
|
Green
|
Actuator power supply
|
1...8 A
|
Yellow
|
Channel status
|
1...8 DIA A
|
Red
|
Periphery error
|
1...8 B
|
Yellow
|
Channel status
|
1...8 DIA B
|
Red
|
Periphery error
|
P1 Lnk/Act
|
Green
Yellow flashing Off
|
Connection to a Profinet device
I/O device exchanging data No connection to any devices
|
P2 Lnk/Act
|
Green
Yellow flashing Off
|
Connection to an Profinet device
I/O device exchanging data No connection to any devices
|
BF
|
Red
Off
|
Bus error, no data exchange with I/O controller
No error
|
DIA
|
Red
Red flashing Off
|
Common indicator for periphery errors
Firmware update No error
|
This M12 distribution block supports both line and ring topologies, using Profinet to send signals from sensors and actuators to the controller. Galvanic isolation creates protection from interference. Each channel can be configured so they behave a certain way if a fault is found. It has reliable and flexible performance, making it perfect for plant and mechanical engineering. Like the other M12 distribution blocks, it withstands exposure from filings, welding sparks, lubricants, and coolants. It can also be found in the automotive industry, as AIDA manufacturers use Profinet as a standard. T distributors can also be used, doubling the amount of available M12 ports.