The Red Lion C48CS113 C48 series panel meter is a standard single preset counter with an NPN OC/relay output. It features a 2 line, 6 digit, transmissive LCD display with backlighting and a 1/16 DIN housing. The backlit screen shows a red digital readout on the main line and a green readout on the second line. It resists noise interference, making it perfect for industrial applications. DC powered.
Features
- One Preset
- Bi-directional & Quadrature Counting
- Dual Line, 6 Digit Transmissive LCD Display w/Backlighting
- Red Top Line & Green Lower Line
- NPN OC/Relay Output
- Up to 11KHz
- NEMA 4X/IP65 - Front Panel
- Field Replaceable Relay Output Board
- Status Indicators for Outputs
- Programmable User Inputs
- Function Keys on Front Panel
- Impact Resistant, Lightweight Black Plastic Housing
- Several Can be Stacked Horizontally or Vertically
Red Lion C48C Series User Manual
Specifications
Display Main Display: 0.3" digits Secondary Display: 0.2" digits Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03 Power Requirements DC Power: 18-36 VDC, 5.5 W max. AC Power: 24 VAC +/- 10%; 50/60 Hz; 7 VA max. Memory Nonvolatile E2PROM retains all programmable parameters and count values Sensor Power +12 VDC (+/- 15%) @100 mA max Count Inputs A & B Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max Debounce: 50 Hz max Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min. Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min User Inputs Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown Response Time: 10 msec max. Inhibit Response Time: 250 usec max. Outputs Solid State: NPN Open Collector- ISNK = 100 mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max. Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load) Relay Life Expectancy: 100,000 cycles min. at max. load rating Standards Compliance UL & CUL Recognized Electrostatic Discharge: EN 61000-4-2 Electromagnetic RF Fields: EN 61000-4-3 Fast Transients (burst): EN 61000-4-4 RF Conducted Interference: EN 61000-4-6 Simulation of Cordless Phone: ENV 50204 RF Interference: EN 55011 Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 70 C (-40 F to 158 F) Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C. Altitude: Up to 2000 meters Housing: Black Plastic Electrical Connection: Wire clamping screw terminals Dimensions: 1.95" x 1.95" x 4.54"
Including nine programmable counting modes, the unit can be adjusted to register counts on both edges of the input signal. Operations such as setting modes & data values, changing the display, and resetting is done via the controls on the front. Data entry is accomplished by digit entry or automatic scrolling. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. The solid state NPN OC open collector operates in parallel to the relay output. The relay output boards are all field replaceable.
|
|
|
|
|
|
|