Home > Panel Meters > C48 1/16 DIN Counters & Timers >

Red Lion Panel Meter, Single Preset Counter, AC, NPN OC/Relay Output


Red Lion C48CS003 Panel Meter
Red Lion C48CS003 Panel Meter, Single Preset Counter, AC, NPN OC/Relay Output
 
Alternative Views:


Price: $237.00
Note: Please call or email [email protected] for alternatives
MFG P/N: C48CS003
MFG: Red Lion
Weight (lbs): 0.38

Quantity in Stock :(Out of Stock)


Availability:
Out of Stock
Product Code: C48CS003
Qty:

Description
 

The Red Lion C48CS003 C48 series panel meter is a standard single preset counter with an NPN OC/relay output. It features a 2 line, 6 digit, reflective LCD display with 1/16 DIN housing. The reflective screen displays positive lit numbers on a negative background. It resists noise interference, making it perfect for industrial applications. AC powered.

Features

  • One Preset
  • Bi-directional & Quadrature Counting
  • Dual Line, 6 Digit Reflective LCD Display
  • NPN OC/Relay Output
  • Up to 11KHz
  • NEMA 4X/IP65 - Front Panel
  • Field Replaceable Relay Output Board
  • Status Indicators for Outputs
  • Programmable User Inputs
  • Function Keys on Front Panel
  • Lightweight Black Plastic Housing Withstands Impact
  • Several Can be Stacked Horizontally or Vertically

Red Lion C48C Series User Manual

Specifications

Display
Main Display: 0.3" digits
Secondary Display: 0.2" digits
Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03
Power Requirements
AC Power: 85-250 VAC, 50/60 Hz, 9 VA max
DC Power: 11-14 VDC @ 150 mA max
Memory
Nonvolatile E2PROM retains all programmable parameters and count values
Sensor Power
+12 VDC (+/- 15%) @100 mA max
Count Inputs A & B
Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC
Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max
Debounce: 50 Hz max
Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min.
Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min
User Inputs
Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC
Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown
Response Time: 10 msec max.
Inhibit Response Time: 250 usec max.
Outputs
Solid State: NPN Open Collector- ISNK = 100 mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max.
Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load)
Relay Life Expectancy: 100,000 cycles min. at max. load rating
Standards Compliance
UL & CUL Recognized
Electrostatic Discharge: EN 61000-4-2
Electromagnetic RF Fields: EN 61000-4-3
Fast Transients (burst): EN 61000-4-4
RF Conducted Interference: EN 61000-4-6
Simulation of Cordless Phone: ENV 50204
RF Interference: EN 55011
Physical
Operating Temperature: 0 C to 50 C (32 F to 122 F)
Storage Temperature: -40 C to 70 C (-40 F to 158 F)
Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C.
Altitude: Up to 2000 meters
Housing: Black Plastic
Electrical Connection: Wire clamping screw terminals
Dimensions: 1.95" x 1.95" x 4.54"

There are nine programmable counting modes & the panel meter can be adjusted to register counts on both edges of the input signal. Programming modes & data values, changing the display, and resetting is done through the controls on the front. Data entry is accomplished by digit entry or automatic scrolling. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. The solid state NPN OC open collector works in parallel to the relay output. The relay output boards are all field replaceable.

Panel Meter Comparison Chart