The Red Lion C48CS003 C48 series panel meter is a standard single preset counter with an NPN OC/relay output. It features a 2 line, 6 digit, reflective LCD display with 1/16 DIN housing. The reflective screen displays positive lit numbers on a negative background. It resists noise interference, making it perfect for industrial applications. AC powered.
Features
- One Preset
- Bi-directional & Quadrature Counting
- Dual Line, 6 Digit Reflective LCD Display
- NPN OC/Relay Output
- Up to 11KHz
- NEMA 4X/IP65 - Front Panel
- Field Replaceable Relay Output Board
- Status Indicators for Outputs
- Programmable User Inputs
- Function Keys on Front Panel
- Lightweight Black Plastic Housing Withstands Impact
- Several Can be Stacked Horizontally or Vertically
Red Lion C48C Series User Manual
Specifications
Display Main Display: 0.3" digits Secondary Display: 0.2" digits Annunciators: Value- PRS, 1, 2, & 3; Output- 01, 02, 03 Power Requirements AC Power: 85-250 VAC, 50/60 Hz, 9 VA max DC Power: 11-14 VDC @ 150 mA max Memory Nonvolatile E2PROM retains all programmable parameters and count values Sensor Power +12 VDC (+/- 15%) @100 mA max Count Inputs A & B Current Sourcing: 3.9KOhm pull-down, VIN max = 30 VDC Current Sinking: 7.8KOhm pull-up to 12 VDC; ISNK = 1.8 mA max Debounce: 50 Hz max Lo Bias: VIL = 1.5 VDC max., VIH = 3.75 VDC min. Hi Bias: VIL = 5.5 VDC max., VIH = 7.5 VDC min User Inputs Current Sinking: VIL = 1.5 VDC max, 22 KOhm pull-up to 5 VDC Current Sourcing: VIH = 3.5 VDC min., VIN max = 30 VDC; 22 KOhm pulldown Response Time: 10 msec max. Inhibit Response Time: 250 usec max. Outputs Solid State: NPN Open Collector- ISNK = 100 mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max. Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load), 1/10 HP @ 120 VAC (inductive load) Relay Life Expectancy: 100,000 cycles min. at max. load rating Standards Compliance UL & CUL Recognized Electrostatic Discharge: EN 61000-4-2 Electromagnetic RF Fields: EN 61000-4-3 Fast Transients (burst): EN 61000-4-4 RF Conducted Interference: EN 61000-4-6 Simulation of Cordless Phone: ENV 50204 RF Interference: EN 55011 Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 70 C (-40 F to 158 F) Humidity: 85% max. relative humidity (non-condensing) from 0 C to 50 C. Altitude: Up to 2000 meters Housing: Black Plastic Electrical Connection: Wire clamping screw terminals Dimensions: 1.95" x 1.95" x 4.54"
There are nine programmable counting modes & the panel meter can be adjusted to register counts on both edges of the input signal. Programming modes & data values, changing the display, and resetting is done through the controls on the front. Data entry is accomplished by digit entry or automatic scrolling. User inputs can be sinking (active low) or sourcing (active high) through a single plug jumper. The solid state NPN OC open collector works in parallel to the relay output. The relay output boards are all field replaceable.
|
|
|
|
|
|
|