More Interfaces
|
Power supply/signaling contact
|
1 plug-in terminal block, 3-pin
|
Network size - Length of cable
|
Twisted pair (TP)
|
0 - 100 m
|
Network size - Cascadibility
|
Line - / star topology
|
any
|
Power requirements
|
Operating voltage
|
18 VDC - 32 VDC
|
Power consumption
|
5.3 Watts
|
Power output in BTU/hr
|
18.1
|
Software
|
Switching
|
TOS/DSCP prioritization (Mapping TOS/DSCP to 802.1D/p), QoS (4 queues), Static unicast/multicast filter entries (up to 100), Flow Control, VLAN Support
|
Redundancy
|
RSTP (IEEE 802.1D-2004), MRP Client
|
Management
|
HTML5 Web-Interface, TFTP config file/firmware transfer, SNMP V1/V2/V3
|
Diagnostics
|
Device status indication (LEDs), Log-File, RMON (1) statistics, Simple interface statistics, Topology Discovery according to IEEE 802.1AB, (LLDP), Syslog
|
Configuration
|
BOOTP/DHCP, HiDiscovery
|
Security
|
SNMPv3 (authNoPriv), Possibility to disable each port, SSH, SSL
|
Time Synchronization
|
SNTP Client
|
Industrial Profiles
|
PROFINET Protocol
|
Presettings |
PROFINET |
Ambient conditions
|
Operating temperature
|
-40 C to +60 C (-40 F to 140 F)
|
Storage/transport temperature
|
-40 C to +85 C (-40 F to 185 F)
|
Relative humidity (non-condensing)
|
5% to 95%
|
Mechanical construction
|
Housing Dimensions - without terminal block
|
45.4 mm Width x 110 mm Height x 82 mm Depth
(1.8" x 4.33" x 3.22")
|
Mounting
|
DIN Rail
|
Weight
|
223 Grams
|
Protection class
|
IP 30
|
Mechanical stability
|
IEC 60068-2-27 shock
|
15 g, 11 ms duration
|
IEC 60068-2-6 vibration
|
3.5 mm, 5–8.4 Hz, 10 cycles, 1 octave/min; 1 g, 8.4–150 Hz, 10 cycles, 1 octave/min |
EMC interference immunity
|
EN 61000-4-2 electrostatic discharge (ESD)
|
4 kV contact discharge, 8 kV air discharge
|
EN 61000-4-3 electromagnetic field
|
10 V/m (80 MHz - 1 GHz), 3 V/m (1,4 GHz – 6GHz)
|
EN 61000-4-4 fast transients (burst)
|
2 kV power line, 2 kV data line
|
EN 61000-4-5 surge voltage
|
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
|
EN 61000-4-6 conducted immunity
|
10 V (150 kHz-80 MHz)
|
EMC emitted immunity
|
FCC CFR47 Part 15
|
FCC 47 CFR Part 15 Class A
|
EN 55032
|
EN 55032 Class A
|
Approvals
|
Safety of industrial control equipment
|
cUL 61010-1
|
Scope of delivery
|
Scope of delivery
|
device, terminal block, safety & general info sheet (SFP transceivers sold separately)
|