More Interfaces
|
Power supply/signaling contact
|
1 plug-in terminal block, 3-pin
|
Network size - Length of cable
|
Twisted pair (TP)
|
0 - 100 m
|
Multimode fiber (MM) 50/125
|
0 - 5000 m (Link Budget at 1310 nm = 0 - 8 dB; A=1 dB/km; BLP = 800 MHz*km)
|
Multimode fiber (MM) 62.5/125
|
0 - 4000 m (Link Budget at 1300 nm = 0 - 11 db; A = 1 dB/km; BLP = 500 MHz*km)
|
Network size - Cascadibility
|
Line - / star topology
|
any
|
Power requirements
|
Current consumption at 24 V DC
|
Max. 83 mA
|
Operating voltage
|
12/24V DC (9.6 VDC - 32 VDC)
|
Power consumption
|
Max. 2 W, 7 Btu (IT)/h
|
Power output in Btu (IT) h
|
7
|
Service
|
Diagnostics
|
LEDs (power, link status, data, data rate)
|
Ambient conditions
|
Operating temperature
|
0 C to +60 C
|
Storage/transport temperature
|
-40 C to +70 C
|
Relative humidity (non-condensing)
|
0% to 95%
|
MTBF (Telecordia)
|
2,705,181 hours
|
Mechanical construction
|
Dimensions (W x H x D)
|
26 mm x 102 mm x 79 mm (w/o terminal block)
|
Mounting
|
DIN Rail
|
Weight
|
100 g
|
Protection class
|
IP 30
|
Mechanical stability
|
IEC 60068-2-27 shock
|
15 g, 11 ms duration, 18 shocks
|
IEC 60068-2-6 vibration
|
3.5 mm, 5-8.4 Hz, 10 cycles,
1 octave/min; 1 g, 8.4-150 Hz, 10 cycles, 1 octave/min
|
EMC interference immunity
|
EN 61000-4-2 electrostatic discharge (ESD)
|
4 kV contact discharge, 8 kV air discharge
|
EN 61000-4-3 electromagnetic field
|
10 V/m (80 - 1000 MHz)
|
EN 61000-4-4 fast transients (burst)
|
2 kV power line, 4 kV data line
|
EN 61000-4-5 surge voltage
|
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
|
EN 61000-4-6 conducted immunity
|
10 V (150 kHz - 80 MHz)
|
EMC emitted immunity
|
FCC CFR47 Part 15
|
FCC 47 CFR Part 15 Class A
|
EN 55022
|
EN 55022 Class A
|
Approvalss
|
Basis Standard
|
CE, FCC, EN61131
|
Safety of industrial control equipment
|
cUL61010-1/61010-2-201
|
Scope of delivery
|
Scope of delivery
|
device, terminal block, safety instruction
|