More Interfaces
|
Power supply/signaling contact
|
1 x M12 5-pin connector, A coding / no signal contact (fault relays)
|
Network size - Length of cable
|
Twisted pair (TP)
|
0 - 100 m
|
Network size - Cascadibility
|
Line - / star topology
|
any
|
Power requirements
|
Operating voltage
|
9.6 - 32 V DC
|
Power consumption
|
max. 2.4 W
|
Current consumption at 24 V DC
|
max. 100 mA
|
Service
|
Diagnostics
|
LEDs (power, link status, data)
|
Ambient conditions
|
Operating temperature
|
-40 C to +70 C
|
Storage/transport temperature
|
-40 C to +85 C
|
MTBF
|
135.6 years; MIL-HDBK 217F: Gb 25 C
|
Mechanical construction
|
Dimensions (W x H x D)
|
60 mm x 126 mm x 31 mm
|
Mounting
|
Wall mounting
|
Weight
|
210 g
|
Protection class
|
IP67
|
Mechanical stability
|
IEC 60068-2-27 shock
|
15 g, 11 ms duration, 18 shocks
|
IEC 60068-2-6 vibration
|
3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
|
EMC interference immunity
|
EN 61000-4-2 electrostatic discharge (ESD)
|
4 kV contact discharge, 8 kV air discharge
|
EN 61000-4-3 electromagnetic field
|
10 V/m (80 - 1000 MHz)
|
EN 61000-4-4 fast transients (burst)
|
2 kV power line, 1 kV data line
|
EN 61000-4-5 surge voltage
|
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
|
EN 61000-4-6 conducted immunity
|
10 V (150 kHz - 80 MHz)
|
EMC emitted immunity
|
FCC CFR47 Part 15
|
FCC CFR47 Part 15 Class A
|
EN 55022
|
EN 55022 Class A
|
Approvals
|
Safety of industrial control equipment
|
cUL 508
|
Employment in vehicles
|
E1
|
Scope of delivery and accessories
|
Scope of delivery
|
2 covers for sealing unused ports, M12-connector for power connection, description and operating instructions
|