The Hirschmann M-FAST SFP-MM/LC EEC (P/N: 943865-001) is an SFP fiber optic fast Ethernet transceiver. Multimode fiber with LC style connector. Has an extended operating temperature range.
Specifications
Network Size - Length of Cable
- Multimode fiber (MM) 50/125 µm: 0 - 5000 m 0 - 8 dB link budget at 1310 nm A = 1 dB/km, 3 dB Reserve, B = 800 MHz x km
- Multimode fiber (MM) 62.5/125 µm: 0 - 4000 m 0 - 11 dB link budget at 1310 nm A = 1 dB/km, 3 dB Reserve, B = 500 MHz x km
Power Requirements
- Operating voltage: Power supply via the switch
- Power Consumption: 1 W
Service
- Diagnostics: Optical input- and output power, transceiver temperature
Ambient Conditions
- Operating temperature: -40 C to 85 C
- Storage temperature: -40 C to 85 C
- Relative humidity: 10% to 95%
- MTBF: 514 years; Telcordia SR-332
Mechanical Construction
- Dimensions: 20 mm x 18 mm x 50 mm
- Mounting: SFP Slot
- Weight: 40 g
- Protection Class: IP 20
Mechanical Stability
- IEC 60068-2-27 shock: 15 g, 11 ms duration 18 shocks
- IEC 60068-2-6 vibration: 1 mm, 2 Hz - 13,2 Hz, 90 min.; 0,7g, 13,2 Hz - 100 Hz, 90 min.; 3,5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC Interference Immunity
- EN 61000-4-2 electrostatic discharge (ESD): 6 kV contact discharge, 8 kV air discharge
- EN 61000-4-3 electromagnetic field: 10 V/m (80 - 1000 MHz)
- EN 61000-4-4 fast transients (burst): 2 kV power line, 1 kV data line
- EN 61000-4-5 surge voltage: power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line
- EN 61000-4-6 conducted immunity: 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC Emitted Immunity
- FCC CFR47 Part 15: FCC CFR47 Part 15 Class A
- EN 55022: EN 55022 Class A
Approvals
- Safety of information technology equipment: cUL 60950-1
- Shipbuilding: Germanischer Lloyd
Accessories
- To order separately: SFP module
Hirschmann 943945-001 Fast Ethernet SFP Transceiver
|
|
|
|
|
|
|